{"product_id":"fip100-fiber-inspection-probe-1","title":"Fiber Inspection Probe Kit","description":"\u003ch4\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/RoHS.png?v=1711744737\" alt=\"\" width=\"55\" height=\"74\"\u003e\u003c\/h4\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThis Fiber Inspection Probe\u003c\/strong\u003e is a fully automated inspection tool that provides fast and reliable analysis of fiber optic connector end faces and bulkheads.\u003c\/p\u003e\n\u003cp\u003eWith a single button press, the Fiber Inspection Probe tool automatically focuses, captures an image of the connector endface, and provides a pass\/fail result.\u003c\/p\u003e\n\u003cp\u003eThe pass\/fail status of the connector is instantly reported via a red\/green LED on the probe. Detailed results are shown on the iOS or Android app, which provides PDF report generation and sharing.\u003c\/p\u003e\n\u003cp\u003eBoth apps are pre-loaded with pass\/fail requirements from IEC 61300-3-35, as required by all major telecommunications service providers. \u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eProduct Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTest ferrule end faces and bulkheads compliant to IEC61300-3-35\u003c\/li\u003e\n\u003cli\u003e Single-handed, one-button operation\u003c\/li\u003e\n\u003cli\u003eAuto focus, auto-capture, auto test\u003c\/li\u003e\n\u003cli\u003eLED pass\/fail indicator on probe\u003c\/li\u003e\n\u003cli\u003eSmall form factor enables inspection of difficult-to-reach ports\u003c\/li\u003e\n\u003cli\u003eCreate and share reports on Android and iOS devices, IEC, IPC, and user-defined inspection criteria\u003c\/li\u003e\n\u003cli\u003eWide range of adapter tips\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify connector cleanliness before connecting\u003c\/li\u003e\n\u003cli\u003eCertify connector condition on installation\u003c\/li\u003e\n\u003cli\u003eDocument connector damage when troubleshooting\u003c\/li\u003e\n\u003cli\u003eInspection is essential for proper fiber handling in all networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePass\/fail results in seconds: \u003c\/strong\u003eWith the press of a single button, the FIP100 auto-focuses, captures, centers, and analyzes the end-face image to industry standard IEC 61300-3-35, IPC-8497-1, AT\u0026amp;T TP-76461 and other user-defined criteria.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUntethered operation: \u003c\/strong\u003eOne-button operation and pass\/fail LED indicator enable operation without reference to the mobile app.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWide range of adapter tips: \u003c\/strong\u003eInterchangeable adapter tips support fiber connector inspection for a wide range of patch cords and bulkhead-mounted connectors having either PC\/UPC or APC polished end-faces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSmart Device Apps:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuto focus, auto capture, and auto test functions\u003c\/li\u003e\n\u003cli\u003eIEC, IPC, industry standard, and user-defined inspection rules\u003c\/li\u003e\n\u003cli\u003ePinch-to-zoom fiber end-face images\u003c\/li\u003e\n\u003cli\u003eReport generation\u003c\/li\u003e\n\u003cli\u003eMulti-language Graphical User Interface (GUI)\u003c\/li\u003e\n\u003cli\u003eDay\/time-stamped job saving\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/FIP100-manual2024_02_06.pdf?v=1769712570\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFIP100 Manual\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/FIP100-manual2023_08_29-es.pdf?v=1769712569\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFIP100 Manual (Español)\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/FIP100_DATASHEET_REV2_2024-12-30-183315_bxls.pdf?v=1769712569\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFIP100 Datasheet\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/SP_FIP100_DATASHEET_REV1.pdf?v=1769712569\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eFIP100 Datasheet (Español)\u003c\/button\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/DoC_FIP100_2025-01-28-005223_pbsj.pdf?v=1769712569\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eDoC FIP100 (2025)\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable class=\"table table-bordered table-striped text-center\" width=\"100%\"\u003e\n\u003cthead\u003e\n\u003ctr bgcolor=\"F8C535\"\u003e\n\u003cth colspan=\"2\"\u003eTECHNICAL SPECIFICATIONS\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr bgcolor=\"F2E9D7\"\u003e\n\u003cth colspan=\"2\" style=\"text-align: center;\" class=\"table-active\"\u003eOPTICAL PERFORMANCE\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eFIELD OF VIEW (FOV)\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eLIVE AND CAPTURED: 612 X 460 μM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"F2E9D7\"\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eMANUAL DETECTION CAPABILITY (MINIMUM)\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.25 μM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eAUTO ANALYSIS RESOLUTION\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u0026lt;1.0 μM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"F2E9D7\"\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eSTORED IMAGE SIZE\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e2592 X 1944 (5M) PIXELS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eEND-FACE ILLUMINATION\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eCOAXIAL BLUE LED 476 NM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"F2E9D7\"\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eMAXIMUM NO DAMAGE LIVE FIBER POWER LEVEL\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e+20 DBM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"text-align: center;\" class=\"table-active\"\u003eOPERATING FEATURES\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"F2E9D7\"\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eWIFI CHARACTERISTICS\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eIEEE 802.11BNG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eFOCUS\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eAUTO-FOCUS (≤3 SEC) AND MANUAL FOCUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"F2E9D7\"\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eCENTERING\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eAUTO-CENTERING (\u0026lt;1 SEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eBUTTON FUNCTIONALITY\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003ePOWER ON\/OFF (\u0026gt;3 SECS); CAPTURE\/ANALYSIS\/AUTO-SAVE\/LIVE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"F2E9D7\"\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eMAIN LED FUNCTIONALITY\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eBLUE = CONNECTED TO APP, GREEN = PASS, RED = FAIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eMAGNIFICATION\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eVARIABLE FROM 80X TO 700X, IN LIVE AND CAPTURE MODES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"F2E9D7\"\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eAPPLICATIONS COMPATIBILITY\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eANDROID ≥4.0.3, IOS ≥8.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eIMAGE CAPTURE WITH PASS\/FAIL ANALYSIS\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eIEC 61300-3-35, AT\u0026amp;T TP-76461, IPC-8497-1, USER-SET CRITERIA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"F2E9D7\"\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eIMAGE FILE FORMAT\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eJPEG, GIF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eIMAGE \u0026amp; PASS\/FAIL RESULTS STORAGE\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eYES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"F2E9D7\"\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eFILE STORAGE CAPACITY\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eUNLIMITED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eRESULT MANAGER\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eSTORAGE, RENAME, DELETE, TRANSFER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"F2E9D7\"\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eREPORTING\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eBUILT-IN FILLABLE PDF REPORTER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eSUPPORTED LANGUAGES\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eENGLISH, FRENCH, GERMAN, JAPANESE, KOREAN, RUSSIAN, SPANISH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"F2E9D7\"\u003e\n\u003cth colspan=\"2\" style=\"text-align: center;\" class=\"table-active\"\u003ePHYSICAL AND POWER CHARACTERISTICS\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eBATTERY TYPE\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eLI-ION, NON-REPLACEABLE BY USER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"F2E9D7\"\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eMAXIMUM CHARGER CURRENT DRAW\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e1.2A, BATTERY CHARGE CURRENT + DEVICE CONSUMPTION CURRENT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eOPERATING TIME (TYPICAL)\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e60 HOURS D; 8 HOURS CONTINUOUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"F2E9D7\"\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eRECHARGE TIME\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e≤4 HOURS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eLOW-BATTERY WARNING\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eVIEWED ON SMART DEVICE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"F2E9D7\"\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eCHARGING LED STATUS; VIEWED ON SMART DEVICE\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eRED = CHARGING, GREEN = FULLY CHARGED, BLINKING RED\/GREEN = BATTERY FAULT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003ePOWER SAVE FEATURES (CONTROLLED BY APP)\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003ePROBE AUTO-OFF – DISABLED, 5, 10, 30, 60 MINUTES; PROBE WIFI NOT CONNECTED – 5 MINUTES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"F2E9D7\"\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eAC CHARGER VOLTAGE, FREQUENCY, CURRENT\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e100-240VAC, 50\/60HZ, 5VDC, 2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eCHARGER JACK\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.9 X 3.2 MM BARREL, CENTER (TIP) POSITIVE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"F2E9D7\"\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eSIZE (MAX DIAMETER X LENGTH)\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eØ 40 X 226 MM (Ø 1.6 X 8.9 IN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eWEIGHT\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e150 G (5.3 OZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"F2E9D7\"\u003e\n\u003cth colspan=\"2\" style=\"text-align: center;\" class=\"table-active\"\u003eENVIRONMENTAL CHARACTERISTICS\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eOPERATING TEMPERATURE\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e0 TO +50 °C; 95% RH, NON-CONDENSING\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"F2E9D7\"\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eSTORAGE TEMPERATURE\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e-40 TO +70 °C; 95% RH, NON-CONDENSING\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"text-align: center;\" class=\"table-active\"\u003eCOMPLIANCE\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"F2E9D7\"\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eCE\/UKCA EU\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eCOMPLIANT TO RELEVANT EU DIRECTIVES ON HEALTH, SAFETY, AND ENVIRONMENTAL PROTECTION, AND CERTIFIED WITH CE MARKING\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eSAFETY\/EMC\/EMI IEC\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eCOMPLIANT TO IEC 61010-1 FOR SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"F2E9D7\"\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eEN\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eCOMPLIANT TO EN 55011 FOR EMC REQUIREMENTS FOR INDUSTRIAL, SCIENTIFIC AND MEDICAL EQUIPMENT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eFCC\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eCOMPLIANT TO CODE OF FEDERAL REGULATIONS FCC 47 CFR 15 ON UNLICENSED TRANSMISSIONS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"F2E9D7\"\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eROHS EU\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eCOMPLIANT TO EU REGULATIONS DIRECTIVE 2011\/65\/EU (ROHS 2) AND DIRECTIVE 2015\/863 (ROHS 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eTEST METHOD IEC\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eCOMPLIANT TO IEC 61300-3-35 FOR VISUAL INSPECTION OF FIBER OPTIC CONNECTORS AND FIBER-STUB TRANSCEIVERS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"F2E9D7\"\u003e\n\u003cth style=\"text-align: center;\" scope=\"row\" class=\"table-active\"\u003eIPC\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eCOMPLIANT TO IPC-8497-1 FOR CLEANING METHODS AND CONTAMINATION ASSESSMENT FOR OPTICAL ASSEMBLY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch4\u003eAdditional Information\u003c\/h4\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable class=\"table table-bordered text-center\" width=\"100%\"\u003e\n\u003cthead\u003e\n\u003ctr bgcolor=\"F8C535\"\u003e\n\u003cth colspan=\"2\" style=\"padding: 12px; border: 1px solid #ccc; text-align: center;\"\u003eProduct Videos\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr bgcolor=\"F2E9D7\"\u003e\n\u003ctd style=\"width: 50%; padding: 16px; vertical-align: top; border: 1px solid #ccc; text-align: center;\"\u003e\n\u003ch3 style=\"margin-top: 0;\"\u003eINSPECTION PROBE TOOL, FOR QUICKLY IDENTIFYING FIBER OPTIC CABLE FAULTS\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cdiv style=\"position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/yjUycYLQfBw?si=y8GZC16ax7Z24klQ\" style=\"position: absolute; top: 0; left: 0; width: 100%; height: 100%;\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50%; padding: 16px; vertical-align: top; border: 1px solid #ccc; text-align: center;\"\u003e\n\u003ch3 style=\"margin-top: 0;\"\u003eLESS COMMON TIPS FOR FIBER INSPECTION PROBE | LONG LC? MPO? WE'VE GOT YOU COVERED!\u003c\/h3\u003e\n\u003cdiv style=\"position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/elv2oxMdnV0?si=dSXzPg_UFBnnJJE4\" style=\"position: absolute; top: 0; left: 0; width: 100%; height: 100%;\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch4\u003eWhat's in the Box\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat's in the Box\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQty 1 - Fiber Inspection Probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eQty 1 - Power supply with NA, UK \u0026amp; EU plug adapters\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eQty 1 - SC\/UPC bulkhead tip \u0026amp; SC\/UPC bulkhead\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eQty 1 - Carry case\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eQty 1 - Quick reference card\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Tempo","offers":[{"title":"Probe Kit","offer_id":54481543135596,"sku":"FIP100 KIT","price":1404.0,"currency_code":"USD","in_stock":true},{"title":"Probe Kit - SC\/APC","offer_id":54481543168364,"sku":"FIP100 KIT - SC\/APC","price":1497.6,"currency_code":"USD","in_stock":true},{"title":"Probe Kit - LC\/UPC","offer_id":54481543201132,"sku":"FIP100 KIT - LC\/UPC","price":1497.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/FIP100_KIT_-_1.jpg?v=1790181401","url":"https:\/\/www.fibersavvy.com\/products\/fip100-fiber-inspection-probe-1","provider":"Fiber Savvy","version":"1.0","type":"link"}