{"product_id":"tight-buffer-distribution-plenum-ofnp-fiber-optic-cable-multimode-om3-afl-fiber-indoor-outdoor-6-strand","title":"Tight Buffer Distribution Plenum OFNP Fiber Optic Cable, Multimode, OM3,Fiber Cable, Indoor\/Outdoor, 6 strand","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center; font-weight: bold; font-size: 16px !important; font-style: italic; color: #b42024; width: 650px !important; background: #e6e6e6; border: 2px solid #b42024 !important; border-radius: 6px;\" class=\"eol-notice\"\u003eThis item is final sale and is not eligible for return, exchange, refund, or order cancellation. Please review product details carefully.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"65px\" width=\"115px\" class=\"bulleticons\" alt=\"Made in USA\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Made_In_USA.png?2208\"\u003e \u003cimg height=\"75px\" width=\"55px\" class=\"bulleticons\" alt=\"RoHS Compliant\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/Bullets-_RoHS.jpg?2209\"\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e(We do not offer credits or returns for this item.)\u003c\/h3\u003e\n\u003ch3\u003eThis fiber cable is priced per foot with a minimum order length of 895ft.\u003c\/h3\u003e\n\u003ch3\u003e\n\u003cb\u003eNote: \u003c\/b\u003eOrders over 4,000ft must ship freight and require a shipping quote. To request a shipping quote email us or call us.\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eIf you would like to inquire about our custom fiber cable options such as terminated ends, or pulleys please call or email us.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch2\u003eMultimode OM3 Indoor\/Outdoor Plenum Distribution Fiber Optic Cable with Fiber Cable\u003c\/h2\u003e\n\u003cp\u003eIndoor\/Outdoor Tight Buffered cables are specified for campus network cabling between buildings where interbuilding lengths are short enough that the installer can recognize savings from the lower costs of terminating tight buffered cables.\u003c\/p\u003e\n\u003cp\u003eFor indoor applications, the cable is OFNP listed. For outdoor applications, the cable is manufactured with an outer jacket that incorporates a UV stabilizer for protection against exposure to the sun plus an anti-fungus protection for use in underground applications.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCleaning your fiber connector end faces and components regularly is crucial for avoiding a total network failure. Ensure your optical fiber system is working properly and prevent major network issues with \u003c\/span\u003e\u003ca alt=\"Fiber Cleaning Kits\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-kit\" target=\"_blank\"\u003efiber cleaning kits,\u003c\/a\u003e \u003ca alt=\"Fiber Cleaning Pens\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-pens\" target=\"_blank\"\u003epens,\u003c\/a\u003e\u003ca alt=\"Fiber Cleaning Fluids\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-fluids\" target=\"_blank\"\u003e fluids,\u003c\/a\u003e and \u003ca alt=\"Fiber Cleaning Wipes\" href=\"https:\/\/www.primuscable.com\/collections\/fiber-cleaning-wipes\" target=\"_blank\"\u003ewipes.\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCables are water-blocked and meet water penetration requirements of GR-20-CORE (this helps ensure that any damage to the cable is restricted to a repairable length of several meters and minimizes the likelihood of having to replace the entire cable)\u003c\/li\u003e\n\u003cli\u003eOuter jacket is moisture-resistant, fungus-resistant, and UV-resistant for outdoor use\u003c\/li\u003e\n\u003cli\u003eWith a plenum rating, this cable can be used in all environments: plenum, riser, general inside plant, and outside plant\u003c\/li\u003e\n\u003cli\u003eTested to meet or exceed EIA\/TIA 568-A \/ GR-409-CORE\u003c\/li\u003e\n\u003cli\u003eCompliant to Directive 2002\/95\/EC (RoHS)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eICEA S-104-696\u003c\/li\u003e\n\u003cli\u003eTelcordia GR-409-Core Issue II Weatherized Cable\u003c\/li\u003e\n\u003cli\u003eEIA\/TIA 568\u003c\/li\u003e\n\u003cli\u003eRoHS\/REACH Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0252\/1897\/3741\/files\/IO-Plenum-Distribution-Cable-SCRUB__KQ006L641801.pdf?v=1777331959\" target=\"_blank\"\u003e \u003cbutton class=\"download-btn\"\u003eSpec Sheet\u003c\/button\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- Temperature Specifications (single column, centered \u0026 caps) --\u003e\n\u003ctable class=\"table table-bordered text-center\" width=\"100%\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eTEMPERATURE SPECIFICATIONS\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-transform: uppercase; font-weight: 600;\"\u003eINSTALLATION\u003c\/td\u003e\n\u003ctd style=\"text-transform: uppercase; font-weight: 600;\"\u003e0ºC TO +70ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-transform: uppercase; font-weight: 600;\"\u003eOPERATING\u003c\/td\u003e\n\u003ctd style=\"text-transform: uppercase; font-weight: 600;\"\u003e-40ºC TO +70ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-transform: uppercase; font-weight: 600;\"\u003eSTORAGE\u003c\/td\u003e\n\u003ctd style=\"text-transform: uppercase; font-weight: 600;\"\u003e-40ºC TO +70ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- Mechanical Data --\u003e\n\u003ctable class=\"table table-bordered text-center\" width=\"100%\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"8\"\u003eMECHANICAL DATA\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAFL NO.\u003c\/th\u003e\n\u003cth\u003eFIBER COUNT\u003c\/th\u003e\n\u003cth\u003eDIAMETER (INCHES \/ MM)\u003c\/th\u003e\n\u003cth\u003eWEIGHT LBS\/1000FT (KG\/KM)\u003c\/th\u003e\n\u003cth\u003eTENSILE STRENGTH LBS (N) — INSTALLATION\u003c\/th\u003e\n\u003cth\u003eTENSILE STRENGTH LBS (N) — LONG TERM\u003c\/th\u003e\n\u003cth\u003eBEND RADIUS INCHES (CM) — INSTALLATION\u003c\/th\u003e\n\u003cth\u003eBEND RADIUS INCHES (CM) — LONG TERM\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"table-active\"\u003eKQ002‹461#01\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e0.18 (4.6)\u003c\/td\u003e\n\u003ctd\u003e15 (22)\u003c\/td\u003e\n\u003ctd\u003e150 (667)\u003c\/td\u003e\n\u003ctd\u003e45 (200)\u003c\/td\u003e\n\u003ctd\u003e2.7 (6.9)\u003c\/td\u003e\n\u003ctd\u003e1.8 (4.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"table-active\"\u003eKQ004‹501#01\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e0.20 (5.0)\u003c\/td\u003e\n\u003ctd\u003e17 (26)\u003c\/td\u003e\n\u003ctd\u003e150 (667)\u003c\/td\u003e\n\u003ctd\u003e45 (200)\u003c\/td\u003e\n\u003ctd\u003e3.0 (7.5)\u003c\/td\u003e\n\u003ctd\u003e2.0 (5.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"table-active\"\u003eKQ006‹541#01\u003c\/th\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e0.21 (5.4)\u003c\/td\u003e\n\u003ctd\u003e20 (30)\u003c\/td\u003e\n\u003ctd\u003e150 (667)\u003c\/td\u003e\n\u003ctd\u003e45 (200)\u003c\/td\u003e\n\u003ctd\u003e3.2 (8.1)\u003c\/td\u003e\n\u003ctd\u003e2.1 (5.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"table-active\"\u003eKQ012‹611#01\u003c\/th\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e0.24 (6.1)\u003c\/td\u003e\n\u003ctd\u003e27 (40)\u003c\/td\u003e\n\u003ctd\u003e150 (667)\u003c\/td\u003e\n\u003ctd\u003e45 (200)\u003c\/td\u003e\n\u003ctd\u003e3.6 (9.1)\u003c\/td\u003e\n\u003ctd\u003e2.4 (6.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"table-active\"\u003eKQ024‹791#01\u003c\/th\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e0.31 (7.9)\u003c\/td\u003e\n\u003ctd\u003e46 (69)\u003c\/td\u003e\n\u003ctd\u003e150 (667)\u003c\/td\u003e\n\u003ctd\u003e45 (200)\u003c\/td\u003e\n\u003ctd\u003e4.7 (11.9)\u003c\/td\u003e\n\u003ctd\u003e3.1 (7.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eAdditional Information\u003c\/h4\u003e\n\u003ch3\u003eMultimode Fiber Information\u003c\/h3\u003e\n\u003cp\u003eMulti-Mode cable commonly has a diameter in the 50-to-100 micron range (typical multimode fiber core diameters are 50 or 62.5 micrometers). Multimode fiber gives you high bandwidth at high speeds (10 to 100MBS - Gigabit to 275m to 2km) over medium distances. Light waves are dispersed into numerous paths, or modes, as they travel through the cable's core typically 850 or 1300nm. However, in long cable runs (greater than 3000 feet [914.4 meters), multiple paths of light can cause signal distortion at the receiving end, resulting in an unclear and incomplete data transmission so designers now call for single mode fiber in new applications using Gigabit and beyond.\u003c\/p\u003e\n\u003ch4\u003eWhat's in the Box\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat's in the Box\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQty 1 – 6-strand Multimode OM3 Tight-buffer Fiber Cable\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eQty 1 – Wooden Reel or Coil (depending on ordered length)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eQty 1 – Protective Outer Packaging (e.g., plastic wrap or box)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Primus Cable","offers":[{"title":"Default Title","offer_id":51947137204588,"sku":"KQ006L641801","price":0.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0079\/8874\/0186\/files\/Distribution-IO-6Fiber_fe02bd4c-8d95-45ae-af46-ee6a16be5dfc.jpg?v=1743713520","url":"https:\/\/www.fibersavvy.com\/products\/tight-buffer-distribution-plenum-ofnp-fiber-optic-cable-multimode-om3-afl-fiber-indoor-outdoor-6-strand","provider":"Fiber Savvy","version":"1.0","type":"link"}